Welcome to Würth Sri Lanka For trade customers only

Fixanchor W-FAZ/A4

Fixanchor W-FAZ/A4 stainless steel
ANC-(W-FAZ/A4)-A4-15-35-M12X110

Art.-no. 5928412015
EAN 4046777116489

Prices for customers after login
Fixanchor W-FAZ/A4

Art.-no. 5928412015

Prices for customers after login
Quantity
PU
x 25 pcs

Exclusively for trade customers

Register now and access more than 2,000 products

  • Approval ETA-99/0011 for individual fixing point, option 1, cracked and uncracked concrete, seismic performance category C1 and C2 (M8-M20)

  • Fire resistance (M8-M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Metric anchor diameter

M12

Anchor length (l)

110 mm

Attachment height (t fix)

15 mm

Max. attachment height reduced (t fix, red)

35 mm

Effective anchoring depth (h ef)

70 mm

Effective anchoring depth reduced (h ef, red)

50 mm

Disc diameter x disc thickness

24 x 2.5 mm

Width across flats

19 mm

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth (h 1)

90 mm

Drill hole depth reduced (h 1, red)

70 mm

Material

Stainless steel A4

Surface

Coated

Torque during anchoring (T inst)

50 Nm

Through-hole in the component to be connected (d f)

14 mm

Thread type x anchor diameter x thread length (L th)

M12 x 51

Approval

ETA-99/0011

Seismology C1

Yes

Seismology C2

Yes

Performance data
Anchor diameter [mm] M8 M10 M12 M16 M20 M24
Standard effective anchorage depth/
Reduced effective anchorage depth

hef/hef,red [mm]
46 353) 60 40 70 50 85 65 100 125
Admissible centric tension load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nadm [kN] = C20/252) 2,4 2,4 4,3 3,6 7,6 6,1 11,9 9,0 17,1 19,0
Compressive zone (uncracked concrete C20/252), (scr,sp and ccr,sp
see approval)
5,7 3,6 7,6 4,3 11,9 8,5 16,7 12,6 24,0 33,6
Permissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
c ≥ 10 hef)
Vadm [kN] = C20/252) 7,4 7,4 11,4 10,4 17,1 14,5 31,4 21,6 43,9 67,1
Compressive zone (uncracked concrete C20/252),
c ≥ 10 hef)
7,4 7,4 11,4 11,4 17,1 17,1 31,4 30,2 43,9 70,6
Permissible bending moment Madm [Nm] 14,9 14,9 29,7 29,7 52,6 _ 114,3 _ 231,6 448,8
Admissible load when exposed to fire (R30, R60, R90, R120) see European Technical Assessment ETA-99/0011
Fire resistance rating F30 [kN] 9,0 _ 15,0 _ 19,0 _ 30,0 _ _ _
F60 [kN] 5,0 _ 9,0 _ 12,0 _ 15,0 _ _ _
F90 [kN] 1,8 _ 4,0 _ 5,0 _ 7,5 _ _ _
F120 [kN] 1,0 _ 2,0 _ 3,0 _ 6,0 _ _ _
Characteristic values
Anchor diameter [mm] M8 M10 M12 M16 M20 M24
Standard effective anchorage depth/
Reduced effective anchorage depth

hef,/hef, red [mm]
46 353) 60 40 70 50 85 65 100 125
Embedment depth hnom [mm] 52 41 68 48 80 60 97 77 114 140
Axis distance Scr,N [mm] 138 105 180 120 210 150 255 195 300 375
Edge distance Ccr,N [mm] 69 52,5 90 60 105 75 127,5 97,5 150 187,5
Standard minimum member thickness hstd ≥ [mm] 100 _ 120 _ 140 _ 160 _ 200 250
Minimum axis distance
Cracked concrete
smin ≥ [mm] 40 _ 50 _ 60 _ 60 _ 95 125
Minimum axis distance
Uncracked concrete
smin ≥ [mm] 40 _ 50 _ 60 _ 65 _ 90 125
Minimum axis distance
Cracked concrete
for c ≥ [mm] 70 _ 75 _ 100 _ 100 _ 150 125
Minimum edge distance
Cracked concrete
cmin ≥ [mm] 40 40 50 65 60 65 80 100 _ _
Minimum edge distance
Uncracked concrete
cmin ≥ [mm] 50 40 90 65 75 100 90 170 _ _
Minimum edge distance
Cracked concrete
for s ≥ [mm] 80 185 115 180 140 250 180 250 _ _
Minimum edge distance
Uncracked concrete
for s ≥ [mm] 100 185 140 180 150 185 200 65 _ _
Nominal drill diameter d0 [mm] 8 10 12 16 20 24

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information